Contact   Sitemap   Impressum    

2 MN Force Standard Machine

Measured quantity: Compression force
Operating principle: Hydraulic with rotating working cylinder; spindle pump for pressure generation, one oil pressure reference transducer
Manufacturer: GTM Gassmann Testing and Metrology GmbH
Measuring ranges: 100 kN to 2000 kN (in any load steps)
DKD-accredited
measuring ranges:
100 kN to 2000 kN (in any load steps)
Expected relative
measuring uncertainty:
  • 5·10-4 in the range from 200 N to 2000 kN
  • 1·10-3 in the range from 100 N to <200 kN
 
defining precision