Contact   Sitemap   Impressum    

Standard Machines

measured
quantity
direction calibration
object
measuring
range
calibration
procedure
lowest specifiable
measuring uncertainty
standard
machine
force tension & compression transducer 100 N to 5 kN ASTM E74
DKD-guideline R3-3
DIN EN ISO376
1·10-4 100 kN force standard machine
5 kN to 100 kN
1 kN to 25 kN 2·10-4 25 kN force standard machine
20 kN to 1200 kN 1.2 MN force standard machine
compression 100 kN to <200 kN 1·10-3 2 MN force standard machine
200 kN to 2 MN 5·10-4
torque clockwise & anticlockwise transducer, measuring chain 5 N·m to 1 kN·m DIN 51309 (class ≥0.1)
EA-10/14 (class ≥0.1)
DKD-R 3-5
2·10-4 5 kN·m torque standard machine
>1 kN·m to 5 kN·m DIN 51309 (class ≥0.05)
EA-10/14 (class ≥0.05)
DKD-R 3-5
1·10-4
reference torque wrench 5 N·m to 2 kN·m DKD-R 3-7 (class ≥0.1) 2·10-4
force & torque tension & compression
clockwise & anticlockwise
multicomponent
transducer
250 N to 1.2 MN
5 N·m to 5 kN·m
  5·10-3 60 kN & 5000 N·m
multicomponent standard machine
voltage ratio     ± 2 mV/V
± 4 mV/V
25 % steps
direct voltage
bridge voltage 10 V
0.2 μV/V  
± 2.5 mV/V
graduation: 0.1;
0.2 to 2.4 mV/V
in steps of 0.2;
2.5
Measurement frequency 225 Hz bridge voltage: 5 V 0.03 μV/V
defining precision