Lever and Deadweight
Technical Data
Capacity between 20 N·m and 5000 N·m
Measuring Uncertainty < 5·10-5 over a range from 0.1% to 100% of capacity
| Capacity
|
Dimensions (H · W · D) in mm
|
Test Space (Length / ø) in mm
|
Overall Weight in kg
|
| 20 N·m
|
1600 · 1700 · 2300
|
700 / 400
|
1050
|
| 50 N·m
|
1600 · 1700 · 2300
|
700 / 400
|
1250
|
| 100 N·m
|
1600 · 1700 · 2300
|
700 / 400
|
1500
|
| 200 N·m
|
1700 · 1900 · 2600
|
900 / 500
|
1500
|
| 500 N·m
|
1700 · 1900 · 2600
|
900 / 500
|
1600
|
| 1000 N·m
|
1700 · 1900 · 2600
|
900 / 500
|
1800
|
| 2000 N·m
|
1800 · 3000 · 3200
|
1200 / 600
|
2500
|
| 5000 N·m
|
2000 · 3600 · 4000
|
1200 / 600
|
3800
|
|
|
|