Force Transfer Standards

Metrology data

Figures in % of reading, in the range of 20% - 100% · Fnom

  GTM Class VN **) Class 00 *) Class 0,5 *) Class 1 *)
Rel. zero return, full scale ds, o ± % 0.008 0.010 0.020 0.035
Rel. reproducibility in unchanged mounting position brg ± % 0.002 0.023 0.045 0.08
Rel. repeatability in changed mounting position brv ± % 0.005 0.045 0.09 0.15
Rel. interpolation error fr ± % 0.002 0.02 0.04 0.08
Rel. hysteresis u ± % 0.06 0.06 0.14 0.25
Temperature coefficient on zero TK0 ± % / K 0.001 0.001 0.002 0.0025
Temperature coefficient on span TKC ± % / K 0.001 0.001 0.002 0.003
Rel. creep error
0,5 - 15 min ≤ 100 kN
1 - 15 min ≥ 200 kN
drc ± % 0.008 0.01 0.02 0.025
Reference temperature Tref ° C 21 21 21 21
Nominal temperature range Bt, nom ° C 21 ± 5 K 10 ... 30 10 ... 30 10 ... 30
Influence of 1 mm eccentricity fm ± % 0.005 0.005 0.01 0.01
*) Definitions according to VDI/VDE 2638 respectively ISO 376
**) better than class 00 according to ISO 376
defining precision