Calibration of force transducers, torque transducers, multi-component transducers and voltage ratio of strain gauge amplifiers

To know in advance:

  • More information about our accredited scope can be found in our accreditation certificate
  • Ranges not covered by our standards will be forwarded to our subcontractor.
  • On request all calibrations are available as factory calibration for reduced prices.
  • Do you need a new calibration method, for example for multicomponent transducers? We will be happy to prove our experience!

Force Transducers, Load Cells, Force Calibration Machines

Procedure/Download
Certificate Example
Application Standards
DIN EN ISO 376Calibration of force transducers used for the calibration of testing machines according DIN EN ISO 7500. 



 

100N-K-BNME
25kN-K-BNME
100kN-K-BNME
1,2MN-K-BNME
10MN-K-BNME

Adaption recommendation:
10 MN Compression
10 MN Tension
Download 3D-PDF

ASTM E-74Calibration of force transducers used for the calibration of testing machines according ASTM E4.
DKD-R 3-3Calibration of force transducers with simplified procedure.
GTM-RL-003Calibration of reference force trancducers used in force calibration machines.
AA 045On-site calibration of force calibration machines.

Torque Transducers, Torque Transfer Wrenches

Procedure/Download 
Calibration Example
Application
Standards
DIN 51309Calibration of torque transducers without transverse force.

5kN·m-Dm-BNME

Adaption
recommendation

DKD-R 3-7Calibration of torque transducers using transverse force, for example torque transfer wrenches.

Multicomponent Transducers, Measuring Platforms

Procedure/Download 
Certificate Example
Application 
Standards
AA 032Calibration of multicomponent transducers with calculation of the main- and secondary sensitivities.
 

MK-BNME

GTM-RL-001Calibration of frictien coefficient sensors in mixed load of axial force and torque.
GTM-RL-002Calibration of multicomponent systems of any type, e.g. measuring platforms, with a representation of the uncertainty vector.

Voltage Ratio, Strain-Gauge Amplifiers

Procedure/Download 
Certificate Example
Application Standards
Carrier frequency 5 V 225 HzCalibration of carrier frequency amplifiers. 




 
Brückennormal BN100A
Kalibriergerät K148

 
Carrier frequency 2,5 V 4,8 kHzCalibration of carrier frequency amplifiers.
Direct current 5 VCalibration of DC amplifiers.
Direct current 10 VCalibration of DC amplifiers.

Our calibration certificates are created in German/English version. The certificates will be recognized in all countries which signed the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC)

Information and advice:
Phone: +49 6257 97 20-0
Contact person
contact@gtm-gmbh.com

Informative documents:
Certificate of Accreditation
Calibration- and delivery conditions

 

 